Type SP
Thermostatic Steam Traps |
Features of Design: • All operating parts easily accessible when
covers are removed.
• Main valve, piston, liner and main seat assembled as a single
cage unit to ensure perfect alignment and ease of maintenance.
• Temperature controller and strainer fitted as standard.
• Optional extras include strainer blow-down valve and Pipe King Package Unit.
• Automatic air venting. |
Range and Duties:
| Type |
Orifice |
Max Temperature |
Pressure Range |
| SP 6-200 |
2 in (50mm) |
850°F (454°C) |
0.34~14 bar |
| SP 7-600 |
2 in (502mm) |
850°F (454°C) |
0.34~42 bar |
| SPF 8-1500 |
2 in (50mm) |
850°F (454°C) |
0.34~105 bar |
Typical Applications:
Reboiders, purifiers, vacuum pans, heat exchangers, evaporators, feed water
heaters, digesters, desuperheaters, steam separators, flash tanks, re-heat
header drains, large autoclaves and other large capacity applications.
Connections: • Screwed: 2 in, 2 1/2 in and 3 in (50mm, 65mm and 80mm) BSP or NPT
• Socket Weld: 2 in, 2 1/2 in and 3 in (50mm, 65mm and 80mm).
• Butt Weld: 2 in, 2 1/2 in and 3 in (50mm, 65mm and 80mm).
• Flanged: 2 in, 2 1/2 in and 3 in (50mm, 65mm and 80mm) BS, ASA or DIN |